Revo OCT
Image description

Optopol Technology develops and manufactures cutting-edge ophthalmic diagnostic equipment, drawing on over 30 years of innovation to create advanced OCT systems and automated perimeters that are trusted by eye care professionals across 90 countries worldwide.

Creator of the world’s 1st Spectral-Domain OCT
Founded in 1992
Revo HR
New

Revo HR

OCT

3 µm High Resolution

130,000 scans/second

AccuTrack™

Retina

Glaucoma

Anterior chamber imaging

Epithelium map

Full Auto

Networking incl. DICOM

Optional Modules

Ultra Wide Field

Angio OCT

Topography

Biometry

IOL formulas

High myopia

Revo FC130

Revo FC130

OCT

130,000 scans/second

AccuTrack™

Retina

Glaucoma

Anterior chamber imaging

Epithelium map

Full Auto

Networking incl. DICOM

Optional Modules

Ultra Wide Field

Angio OCT

Topography

Biometry

IOL formulas

High myopia

Revo FC

Revo FC

OCT

80,000 scans/second

AccuTrack™

Retina

Glaucoma

Anterior chamber imaging

Epithelium map

Full Auto

Networking incl. DICOM

Optional Modules

Ultra Wide Field

Angio OCT

Topography

Biometry

IOL formulas

High myopia

Revo 60

Revo 60

OCT

Spectral Domain OCT

Light SourceSLED, Wavelength 840nm

Bandwidth 50 nm half bandwidth

Scanning speed60,000 A-scan per second

Axial resolution5 µm in tissue

Transverse Resolution12 µm, typical 18 µm

Overall scan depth2.4 mm

Scan range3 to 12 mm

Scan types3D, Radial, B-scan, Raster, Cross

Fundus imageLive Fundus Reconstruction

Alignment methodFully automatic, Semi-automatic

Retina analysis Retina thickness, Inner retinal thickness, Outer retinal thickness, RNFL+GCL+IPL thickness, GCL+IPL thickness, RNFL thickness, RPE deformation, IS/OS thickness

Glaucoma analysis RNFL, ONH morphology, DDLS, Ganglion analysis as RNFL+GCL+IP and GCL+IPL, OU and Hemisphere asymmetry

AnteriorPachymetry, LASIK flap, Angle Assessment, AIOP, AOD 500/750, TISA 500/750

Anterior Wide ScanAngle to Angle view, Adapter required

Min. pupil size3 mm

Focus adjustment range-25D to +25D

Fixation targetOLED display (The target shape and position can be changed), External fixation arm

Revo 80

Revo 80

OCT

Spectral Domain OCT

Light SourceSLED, Wavelength 840nm

Bandwidth50 nm half bandwidth

Scanning speed80,000 A-scan per second

Axial resolution5 µm in tissue

Transverse Resolution12 µm, typical 18 µm

Overall scan depth2.4 mm

Scan range3 to 12 mm

Scan types3D, Radial, B-scan, Raster, Cross

Fundus imageLive Fundus Reconstruction

Alignment methodFully automatic, Semi-automatic

Retina analysisRetina thickness, Inner retinal thickness, Outer retinal thickness, RNFL+GCL+IPL thickness, GCL+IPL thickness, RNFL thickness, RPE deformation, IS/OS thickness

Glaucoma analysisRNFL, ONH morphology, DDLS, Ganglion analysis as RNFL+GCL+IP and GCL+IPL, OU and Hemisphere asymmetry

AnteriorPachymetry, LASIK flap, Angle Assessment, AIOP, AOD 500/750, TISA 500/750

Anterior Wide ScanAngle to Angle view, Adapter required

Min. pupil size3 mm

Focus adjustment range-25D to +25D

PTS 2000

PTS 2000

Visual Field Screener

180° horizontal and 140° vertical test range

All Goldmann stimulus sizes I, II, III, IV, V

White, red, blue, green stimulus color

30-2, 24-2C, 10-2, Central, FF, Armaly, G, N test patterns

ZETA™ thresholding in 3 minutes*

PTS925

PTS925

Visual Field Screener

170° horizontal and 110° vertical test range

Gold standard 10 000 asb white stimulus

30-2, 24-2, 24-2C, 10-2, Ptosis test patterns

ZETA™ thresholding in 3 minutes*

Monocular and binocular testing